Sistemas de Detectores de Incendio Convencionales

C 54

Conventional control unit for fire detection systems. 4 Areas . Max 30 detectors for each area. Compatible EN54/2-4.Dimensions: 269x 386 x 96mm.

BP 212

Optical smoke detector (conventional). Detector coverage up to 40 sqm. Compatible EN54/7-9. Dimensions: diameter 100 x 57 (height)

 

BP 212TP

Conventional thermic detector. Detector coverage up to 40 sqm. Compatible EN54/7-9. Dimensions: diameter 100 x 57 (height)

BPG 213

Solid state detector for domestic gases. Detector coverage 25/30sqm. Dimensions: diameter 100 x 57 (height). Other gases after request.

 

MOD/54 R

Relay outputs optional module. 4 relays associable to alarm events, inclusion/exclusion and blackout.

MOD/54 E

Optional module for managing an electrovalve with programmable delay activation. 4 relays associables to alarm events.

 

ZB/200

Universal socket for optical smoke and rise of temperature detectors in conventional and analogue systems.

ZB/201

Universal relay socket for optical smoke and rise of temperature detectors in conventional and analogue systems.

 

SD 10 GR

Universal relay socket for gas detection sensor

SD 10 G

Universal socket for gas detection sensor

 

P440-P

Conventional key rearming push button

 

Sistema de Direccionamiento para Detectores de Incendio

 

FAP 04

Modular addressable multiprocessor control unit equipped with 1 loop expandable upto 4 loops. 100 addresses for each loop. EN54/2-2 compatible. Dimensions: 482x380x135mm

FDO 10

Addressable optical smoke detector . Detector coverage up to 80 sqm. Compatible EN54/7-9. Dimensions: diameter 100 x 57 (height)

 

FDT 10

Addressabe thermic detector. Detector coverage up to 40 sqm. Compatible EN54/7-9. Dimensions: diameter 100 x 57 (height)

FA 100

Expansion module for addressable loop or open line. Capability up to 100 analogue devices.

 

FA 32 AC

Short-circuit analyzer module for 30 devices or detectors.

FKP 04

Addressable Remote keypad for the repetition and visualisation of active events and commands from the FAP04 control unit.

 

FA PRINT

Interface for parallel printer. Standard opto-isolated CENTRONICS module

FA EI

Input interface for analogue systems. For controlling dry (not pulse) contact devices.

 

FA INT

Input interface for analogue systems. For controlling devices with dry contacts, pulse contacts and for resetting connecting devices.

FA EU

Output interface for analogue systems. Output extension for controlling sounders

 

FDP 02

Addressed push-button protected by safety glass, manual rearming

FA LINK

Programming software for FAP04 analogue systems running on WINDOWS 95/98 and following versions

 

HP 500 F

Self powered outdoor sounder, die casting aluminium case. Flash. Sound output 103 dB at 3 m, 24Vdc. Dimensions: 270 x 210 x 80. Red colour

HS 6/24

Indoor red bell for fire alarm notification. 94 dB (1m), 24Vdc. Diameter 152mm.

 

HS 24F

Piezoelectric 24 Vdc indoor siren. 110 db at 1m. Dimensions: 16,5x11x45mm. Red Colour

IT 24

24/12VVdc terminal module

 

HS TERM

Terminal module (end of line) for controlling and activating bells, sirens, boards, etc..

HS PAS

Intermediate module for controlling and activating bells, sirens, boards, etc..

 

FH 802 F

Xeno optical acoustic board. Sound level 95 dB at 1m, 24 Vdc.

FH 807 F

Two sided XENO optical acoustic board. Sound level 95 dB at 1m, 24 Vdc.

 

FP 20-LR

Outdoor repeater with led,12/24Vdc, red Colour LED

 

Línea de Detectores de Fuego y Humo

 

MINI BOOMERANG

Reflecting infrared fire linear detector. Range max 40m.

FR 100 R

Reflecting infrared fire linear detector. Range max 100m.

 

SF 100

ARDEA TX-RX infrared smoke and fire linear detector.Differentiated processing. Max distance 150m. Coverage area up to 1600sqm per system according to EN54/14

S/2 100

ARDEA TX-RX infrared smoke linear detector.Differentiated processing. Max distance 150m. Coverage area up to 1600sqm per system according to EN54/14

 

INT-8

Interface for ARDEA detectors. It allows connection to NC or NO inputs in the control unit. 24Vdc. IP44.

S-ADM

ARDEA TX-RX infrared smoke linear detector.Differentiated processing. Max distance 150m. Coverage area up to 1600sqm per system according to EN54/14