Sistemas de Detectores de Incendio Convencionales |
|
 |
C 54
Conventional control unit for fire detection systems. 4 Areas . Max 30
detectors for each area. Compatible EN54/2-4.Dimensions: 269x 386 x
96mm. |
|
|
 |
BP 212
Optical smoke detector (conventional). Detector coverage up to 40 sqm.
Compatible EN54/7-9. Dimensions: diameter 100 x 57 (height) |
|
|
 |
BP 212TP
Conventional thermic detector. Detector coverage up to 40 sqm.
Compatible EN54/7-9. Dimensions: diameter 100 x 57 (height) |
|
|
 |
BPG 213
Solid state detector for domestic gases. Detector coverage 25/30sqm.
Dimensions: diameter 100 x 57 (height). Other gases after request. |
|
|
 |
MOD/54 R
Relay outputs optional module. 4 relays associable to alarm events,
inclusion/exclusion and blackout. |
|
|
 |
MOD/54 E
Optional module for managing an electrovalve with programmable delay
activation. 4 relays associables to alarm events. |
|
|
 |
ZB/200
Universal socket for optical smoke and rise of temperature detectors in
conventional and analogue systems. |
|
|
 |
ZB/201
Universal relay socket for optical smoke and rise of temperature
detectors in conventional and analogue systems. |
|
|
 |
SD 10 GR
Universal relay socket for gas detection sensor |
|
|
 |
SD 10 G
Universal socket for gas detection sensor |
|
|
 |
P440-P
Conventional key rearming push button |
|
|
Sistema de Direccionamiento
para Detectores de Incendio |
|
 |
FAP 04
Modular addressable multiprocessor control unit equipped with 1 loop
expandable upto 4 loops. 100 addresses for each loop. EN54/2-2
compatible. Dimensions: 482x380x135mm |
|
|
 |
FDO 10
Addressable optical smoke detector . Detector coverage up to 80 sqm.
Compatible EN54/7-9. Dimensions: diameter 100 x 57 (height) |
|
|
 |
FDT 10
Addressabe thermic detector. Detector coverage up to 40 sqm. Compatible
EN54/7-9. Dimensions: diameter 100 x 57 (height) |
|
|
 |
FA 100
Expansion module for addressable loop or open line. Capability up to 100
analogue devices. |
|
|
 |
FA 32 AC
Short-circuit analyzer module for 30 devices or detectors. |
|
|
 |
FKP 04
Addressable Remote keypad for the repetition and visualisation of active
events and commands from the FAP04 control unit. |
|
|
 |
FA PRINT
Interface for parallel printer. Standard opto-isolated CENTRONICS module |
|
|

|
FA EI
Input interface for analogue systems. For controlling dry (not pulse)
contact devices. |
|
|
 |
FA INT
Input interface for analogue systems. For controlling devices with dry
contacts, pulse contacts and for resetting connecting devices. |
|
|

|
FA EU
Output interface for analogue systems. Output extension for controlling
sounders |
|
|
 |
FDP 02
Addressed push-button protected by safety glass, manual rearming |
|
|
 |
FA LINK
Programming software for FAP04 analogue systems running on WINDOWS 95/98
and following versions |
|
|
 |
HP 500 F
Self powered outdoor sounder, die casting aluminium case. Flash. Sound
output 103 dB at 3 m, 24Vdc. Dimensions: 270 x 210 x 80. Red colour |
|
|
 |
HS 6/24
Indoor red bell for fire alarm notification. 94 dB (1m), 24Vdc. Diameter
152mm. |
|
|
 |
HS 24F
Piezoelectric 24 Vdc indoor siren. 110 db at 1m. Dimensions:
16,5x11x45mm. Red Colour |
|
|

|
IT 24
24/12VVdc terminal module |
|
|
 |
HS TERM
Terminal module (end of line) for controlling and activating bells,
sirens, boards, etc.. |
|
|
 |
HS PAS
Intermediate module for controlling and activating bells, sirens,
boards, etc.. |
|
|
 |
FH 802 F
Xeno optical acoustic board. Sound level 95 dB at 1m, 24 Vdc. |
|
|
 |
FH 807 F
Two sided XENO optical acoustic board. Sound level 95 dB at 1m, 24 Vdc. |
|
|
 |
FP 20-LR
Outdoor repeater with led,12/24Vdc, red Colour LED |
|
|
Línea de Detectores de Fuego y Humo |
|
 |
MINI BOOMERANG
Reflecting infrared fire linear detector. Range max 40m. |
|
|
 |
FR 100 R
Reflecting infrared fire linear detector. Range max 100m. |
|
|
 |
SF 100
ARDEA TX-RX infrared smoke and fire linear detector.Differentiated
processing. Max distance 150m. Coverage area up to 1600sqm per system
according to EN54/14 |
|
|
 |
S/2 100
ARDEA TX-RX infrared smoke linear detector.Differentiated processing.
Max distance 150m. Coverage area up to 1600sqm per system according to
EN54/14 |
|
|
 |
INT-8
Interface for ARDEA detectors. It allows connection to NC or NO inputs
in the control unit. 24Vdc. IP44. |
|
|

|
S-ADM
ARDEA TX-RX infrared smoke linear detector.Differentiated processing.
Max distance 150m. Coverage area up to 1600sqm per system according to
EN54/14 |
|